Measure
angle
Correlation
Output Parameters (Search)
2
Specify how to treat the coordinates to be output to the external device as measurement results.This
item can be changed if necessary.Normally, the factory default value will be used.
Important
After setting up the measurement parameters, changing the output parameters will cause measurement results
●
to vary accordingly.If the output parameters have been changed, re-specify the measurement, too.
1.
Tap [Output parameter] in the Item Tab area.
2.
Specify each of the following items.
Setting item
Output
Coordinates
Calibration
Reflect to
overall
judgement
Key Points for Test Measurement and Adjustment (Search)
The following content is displayed in the "Detail result" area as text.
Important
Executing test measurements will also update the measurement results and the figures in the image.
●
50
Search
-180 to 180
Specify the range of angles that are judged to be OK.
Specify the range of correlation values that are judged to be
0 to 100
OK.However, when the correlation value of the measurement result is
0, the judgement result will be NG regardless of the lower limit setting.
Set value
[factory
default]
[After
●
As measurement results, select whether to output coordinate values
scroll]
to external devices before or after the position deflection correction is
Before
●
applied.
scroll
Select whether to reflect the calibration in the values output to the
[OFF]
external device as measurement results.
●
ON
ON: Output the coordinates converted into actual dimensions.
●
OFF: Output the camera coordinate values.
[ON]
Enables choosing whether or not the judgement results of this
●
OFF
processing unit is reflected in the scene overall judgement.
●
Description
FZ3 Processing Items List Manual