Measurement Parameters (Classification)

Specify the search measurement conditions and the judgement conditions for the measurement results.
1.
In the Item Tab area, tap [Measurement].
2.
In the "Measurement condition" area, specify a value for each item.
2
Setting item
Sub-pixel
Candidate
level
3.
When the setting has been changed, tap [Measurement] in the Detail area to verify whether
measurements can be made correctly.
4.
Set up the judgement condition.
Note
The values beside each item are measurement results of the displayed image.Take these values into
consideration to determine the upper and lower limits.
Setting item
Position X
Position Y
Search
angle
110
Classification
Set value
[factory default]
When a check is placed at sub-pixel, the position information can
Checked
be measured in units of sub-pixels.However, this requires more
[Unchecked]
processing time.
Specify the threshold value with which to detect candidate points
0 to 100
in a rough search.Specify a smaller value when model search
[70]
results are unstable.
Set value
-99999.9999
to
Specify the range of X-axis shifting that is judged to be OK.
99999.9999
-99999.9999
to
Specify the range of Y-axis shifting that is judged to be OK.
99999.9999
-180 to 180
Specify the range of angles that are judged to be OK.
Description