List of Classification Items
Item name
This item registers the pattern characteristic of the measurement image as a model.
Model
Model parameter values can be changed as needed to address unstable measurement results or to
register
increase the processing speed.Normally, the factory default value will be used.
Reference:
This item is used to set up the measurement area.
Region
Instead of measuring the entire input image, narrowing the measurement area shortens the
setting
processing time.
Reference:
This item specifies the judgement condition for measurement results.Specify the criteria to judge the
Measurement
measurement result if the X and Y coordinates and the correlation with the model are OK.
Reference:
This item can be changed if necessary.Normally, the factory default value will be used.
Output
Use the output parameter to specify how to handle the coordinates.
parameter
Reference:

Model Registration (Classification)

Pre-register as models the sections to be used as reference for classification.
Models can be registered with any of 36 indexes, from 0 to 35, and up to 5 models can be registered for
each index.
When there is variation among the model print quality and shapes, pre-register multiple models for the
same index.
1.
In the Item Tab area, tap [Model register].
FZ3 Processing Items List Manual
Model Registration (Classification) (p.105)
Region Setting (Classification) (p.109)
Measurement Parameters (Classification) (p.110)
Output Parameters (Classification) (p.111)
Description