Output Parameters (Edge Position) - Omron XPECTIA FZ3 User Manual

Vision sensor
Hide thumbs Also See for XPECTIA FZ3:
Table of Contents

Advertisement

4.
When the setting has been changed, tap [Measurement] in the Detail area to verify whether
measurements can be made correctly.
5.
Set up the judgement condition.
2
Note
The values beside each item are measurement results of the displayed image.Take these values into
consideration to determine the upper and lower limits.
Setting item
Edge position X
Edge position Y

Output Parameters (Edge Position)

Specify how to treat the coordinates to be output to the external device as measurement results.This
item can be changed if necessary.Normally, the factory default value will be used.
Important
After setting up the measurement parameters, changing the output parameters will cause measurement results
to vary accordingly.If the output parameters have been changed, re-specify the measurement, too.
1.
Tap [Output parameter] in the Item Tab area.
2.
Specify each of the following items.
122
Edge Position
Set value
-99999.9999 to
Specify the range of X-axis shifting that is judged to be
99999.9999
OK.
-99999.9999 to
Specify the range of Y-axis shifting that is judged to be
99999.9999
OK.
Description
FZ3 Processing Items List Manual