Region Setting (Labeling+) - Omron XPECTIA FZ3 User Manual

Vision sensor
Hide thumbs Also See for XPECTIA FZ3:
Table of Contents

Advertisement

Setting item
Threshold
region
2
Filter size
Offset value
Reverse

Region Setting (Labeling+)

This item is used to set up the measurement area.It is possible to measure the entire input image, but
restricting the range enables accurate measurement in a short period of time.
Use a rectangle, straight line, circle (ellipse), wide circle, or polygon to specify a measurement region for
[Labeling+].
1.
In the Item Tab area, tap [Region setting].
2.
Use the Drawing tools to specify the measurement region.
3.
In the figure setting area, specify a region to be measured.
4.
In the figure setting area, tap [OK].
The measurement region is registered and displayed in the Image Display area.
196
Labeling+
Set value
[Factory default]
Set the region to extract.
Light: Pixels brighter than the pixels around them are treated as
white pixels.
[Light]
Dark: Pixels darker than the pixels around them are treated as
Dark
white pixels.
Equal
Equal: Pixels with minimum density difference from the pixels
Not equal
around them are treated as white pixels.
Not equal: Pixels with large density difference from the pixels
around them are treated as white pixels.
Specify the filter size for brightness averaging processing.Match
3 to [255]
this size to the size of the location you want to extract.
This sets the offset for the difference between the input image
0 to 127
and that input image after it has been subject to brightness
[5]
averaging.The higher this value, the easier it is to extract
locations (such as edges) with large density difference.
Checked
This item reverses black and white colors.
[Unchecked]
Description