Item
2
Difference

Measurement Parameters (Fine Matching)

This item specifies the judgement conditions for measurement conditions and measurement results.
1.
In the Item Tab area, tap [Measurement].
2.
Select "Inspection" in the "Measurement condition" area.
230
Fine Matching
Set value
[Factory
default]
This sets the reference grayscale used when calculating differences
between the model and the inspected object image.Pixels with a
difference equal to or greater than Difference are converted to white
and other pixels are converted to black, so that only defects are
converted to white and measured.
0 to 255
[50]
Description