Setting item
Measure
[ Projection]
type
Derivation
[Light → Dark]
Density
Dark → Light
change
Position (%) for width of
●
a density
Edge level
0 to 100 [50]
Value of density
●
0 to 255 [20]
4.
If necessary, set each item in the "Noise removal" area.
Set value
Setting item
[factory
default]
0 to 442
Noise level
[5]
0 to 9999
Noise width
[0]
Judgement Conditions (Scan Edge Width)
Specify the range to be judged as OK.
1.
In the Item Tab area tap [Judgement].
2.
Set up the judgement condition.
Note
The values beside each item are measurement results of the displayed image.Take these values into
●
consideration to determine the upper and lower limits.
FZ3 Processing Items List Manual
Set value
[factory default]
This sets the type of edge measurement.
Select whether a black-to-white change or a
white-to-black change should be recognized as a
density change in the specified region.
Select the density change level to be detected as
edges.
Reference: See "User's Manual", "Edge level" (p.304)
When detection is affected by noise, increase this value.
Reference:
See "User's Manual", "Noise level" (p.305)
Set the width for judging noise.
When detection is affected by noise, increase this value.
Reference:
See "User's Manual", "Noise width" (p.306)
Description
Description
Scan Edge Width
2
151