Judgement Conditions (Scan Edge Width) - Omron XPECTIA FZ3 User Manual

Vision sensor
Hide thumbs Also See for XPECTIA FZ3:
Table of Contents

Advertisement

Setting item
Measure
[ Projection]
type
Derivation
[Light → Dark]
Density
Dark → Light
change
Position (%) for width of
a density
Edge level
0 to 100 [50]
Value of density
0 to 255 [20]
4.
If necessary, set each item in the "Noise removal" area.
Set value
Setting item
[factory
default]
0 to 442
Noise level
[5]
0 to 9999
Noise width
[0]

Judgement Conditions (Scan Edge Width)

Specify the range to be judged as OK.
1.
In the Item Tab area tap [Judgement].
2.
Set up the judgement condition.
Note
The values beside each item are measurement results of the displayed image.Take these values into
consideration to determine the upper and lower limits.
FZ3 Processing Items List Manual
Set value
[factory default]
This sets the type of edge measurement.
Select whether a black-to-white change or a
white-to-black change should be recognized as a
density change in the specified region.
Select the density change level to be detected as
edges.
Reference: See "User's Manual", "Edge level" (p.304)
When detection is affected by noise, increase this value.
Reference:
See "User's Manual", "Noise level" (p.305)
Set the width for judging noise.
When detection is affected by noise, increase this value.
Reference:
See "User's Manual", "Noise width" (p.306)
Description
Description
Scan Edge Width
2
151