Set value
Item
[Factory
default]
Defect
0 to 999
judgement
[100]
Area
0 to A_MAX
judgement
Note
The value beside each item are measurement results of the displayed image.Take these values into
●
consideration to determine the upper and lower limits.
Output Parameters (Defect)
Specifies whether or not the judgement results of this processing unit is reflected in the scene overall
judgement.
1.
Tap [Output parameter] in the Item Tab area.
2.
Choose whether or not to reflect this in the scene overall judgement in "Reflect to overall
judgement" area.
Setting item
Reflect to overall
judgement
Key Points for Test Measurement and Adjustment (Defect)
In the "Detail result" area on the Main screen, you can confirm the following contents in text.
Displayed items
Judge
Judgement result
Defect value
Measured defect level
Defect X
X Coordinate of measured defect position
Defect Y
Y coordinate of measured defect position
Area
The measured maximum defect area
Gravity X
Center of gravity X coordinate of the measured maximum defect area
Gravity Y
Center of gravity Y coordinate of the measured maximum defect area
Key Points for Adjustment
Select the adjustment method referring to the following points.
FZ3 Processing Items List Manual
Specify the upper limit for defect judgement. (The lower limit is fixed at
0.)
When "30" is set, the OK value should be within the range of 0 to 30.
Specify the maximum defect area.
A_MAX: 307,200 for a 0.3-megapixel camera, 1,920,000 for a
2-megapixel camera
Set value
[Factory
default]
[ON]
Enables choosing whether or not the judgement result of this
●
OFF
processing unit is reflected in the scene overall judgement.
●
Description
Description
Description
Defect
215
2