When setting a new model, you do not have to tap [Model register].
2.
Use the drawing tools to specify the model registration range.
3.
In the figure setting area, tap [OK].
The model is registered.
4.
Tap [Edge extraction], then confirm the edge extraction image.
If there is a break in the profile of the measurement object, adjust the edge level.
Reference:
Adjusting the edge level (p.77)
5.
If there is unnecessary profile information in the model, tap [Mask register] to set the mask.
Reference:
Mask any unnecessary items. (p.76)
6.
To check the model display, tap [Display model].
The registered model image is displayed in the image display area.
Note
When a model is registered, the center of the model is registered as the detection point coordinate. A detection
point is a point output as a measurement value.
Changing Model Parameters
Model parameter values can be changed as needed to address unstable measurement results or to
increase the processing speed. Normally, the factory default value will be used.
After changing a setting, check whether measurement can be done properly by performing an actual
measurement.
1.
In the "Model parameter" area, specify a value for each item.
FZ3 Processing Items List Manual
ECM Search
75
2