Omron XPECTIA FZ3 User Manual page 222

Vision sensor
Hide thumbs Also See for XPECTIA FZ3:
Table of Contents

Advertisement

2.
Set the detection parameters.
2
Setting item
Size X
Size Y
Sampling
interval X
Sampling
interval Y
Comparing
interval X
Comparing
interval Y
Direction
220
Precise Defect
Set value
[Factory default]
Specify the X-axis size of defects/contamination to be
4 to 64
detected.The higher this value, the higher the degree of defects
[16]
for large defects. Specify in units of pixels.
Specify the Y-axis size of defects/contamination to be
4 to 64
detected.The higher this value, the higher the degree of defects
[16]
for large defects.Specify in units of pixels.
Specify the interval for creating elements along the X axis.The
1 to 64
smaller this value, the greater the defect detection performance,
[2]
but the slower the processing speed.Specify in units of pixels.
Specify the interval for creating elements along the Y axis.The
1 to 64
smaller this value, the greater the defect detection performance,
[2]
but the slower the processing speed.Specify in units of pixels.
Set the number of neighboring elements compared with when the
degree of defect is calculated,For example, if the Sampling
1 to 32
interval X is set to 4 and the comparing interval X is set to 2,
[10]
comparison is with separate elements of 4 x 2 = 8 pixels along the
X axis.
Set the number of neighboring elements compared with when the
1 to 32
degree of defect is calculated,For example, if the sampling interval
[10]
Y is set to 4 and the comparing interval Y is set to 2, comparison is
with separate elements of 4 x 2 = 8 pixels along the Y axis.
X
Set the direction for detecting defects.
(circumferential)
The smaller the direction setting count, the shorter the processing
Y(radial)
time.
Diagonal
Description
FZ3 Processing Items List Manual

Advertisement

Table of Contents
loading