2.
Set the detection parameters.
2
Setting item
Size X
Size Y
Sampling
interval X
Sampling
interval Y
Comparing
interval X
Comparing
interval Y
Direction
220
Precise Defect
Set value
[Factory default]
Specify the X-axis size of defects/contamination to be
4 to 64
detected.The higher this value, the higher the degree of defects
[16]
for large defects. Specify in units of pixels.
Specify the Y-axis size of defects/contamination to be
4 to 64
detected.The higher this value, the higher the degree of defects
[16]
for large defects.Specify in units of pixels.
Specify the interval for creating elements along the X axis.The
1 to 64
smaller this value, the greater the defect detection performance,
[2]
but the slower the processing speed.Specify in units of pixels.
Specify the interval for creating elements along the Y axis.The
1 to 64
smaller this value, the greater the defect detection performance,
[2]
but the slower the processing speed.Specify in units of pixels.
Set the number of neighboring elements compared with when the
degree of defect is calculated,For example, if the Sampling
1 to 32
interval X is set to 4 and the comparing interval X is set to 2,
[10]
comparison is with separate elements of 4 x 2 = 8 pixels along the
X axis.
Set the number of neighboring elements compared with when the
1 to 32
degree of defect is calculated,For example, if the sampling interval
[10]
Y is set to 4 and the comparing interval Y is set to 2, comparison is
with separate elements of 4 x 2 = 8 pixels along the Y axis.
X
●
Set the direction for detecting defects.
(circumferential)
The smaller the direction setting count, the shorter the processing
Y(radial)
●
time.
Diagonal
●
Description
FZ3 Processing Items List Manual