Measurement Results For Which Output Is Possible (Sensitive Search) - Omron XPECTIA FZ3 User Manual

Vision sensor
Hide thumbs Also See for XPECTIA FZ3:
Table of Contents

Advertisement

Model
parameter
2
Sub-model
parameter
Measurement
parameter

Measurement Results for Which Output Is Possible (Sensitive Search)

The following values can be output using processing items related to results output.It is also possible to
reference measurement values from expressions and other processing units.
Measurement items
Judgement
Correlation value
Deviation
Measurement coordinate X
Measurement coordinate Y
Measurement angle
Reference position X
Reference position Y
Reference angle
Detection point X
Detection point Y
NG Sub-region
Sub-region Number
Sub-region Number(X)
Sub-region Number(Y)
Sub-region Pos. X
Sub-region Pos. Y
Correlation (sub-region N)
(N = 0 to 99)
Deviation (sub-region N)
(N = 0 to 99)
72
Sensitive Search
If the model image is a simple figure or a large figure, specify a smaller value for "Stab."If lowering
stability does not speed up processing, it is likely that many candidates have been detected. Raise
the "Candidate level" in [Measurement].
When "Rotation" is selected and the model image is a simple figure, specify a larger value for
"Skipping angle".
When "Rotation" is selected and the model image is a simple figure, place a check at "Smart mode".
If the position precision is high, specify a smaller value for "Prec.".
If images that should be judged OK vary greatly, specify a larger value for "Sub-model number X"
and "Sub-model number Y".
If images that should be judged OK vary little, specify a larger value for "Candidate level".
If the position precision is high, uncheck "Sub-pixel".
Character
string
JG
CR
DV
X
Y
TH
SX
SY
ST
RX
RY
CT
AN
ANX
ANY
DX
DY
CRN
DVN
Description
Judgement result
Correlation with the model
Deviation
X coordinate of the position where the model is detected
Y coordinate of the position where the model is detected
Angle of the position where the model is detected
X coordinate of the reference position of the registered model
Y coordinate of the reference position of the registered model
Angle of the registered model
X coordinate of the registered model
Y coordinate of the registered model
NG region count
Region number with the lowest correlation value
X direction column number for the output region
Y direction line number for the output region
X coordinate of the detected sub-region
Y coordinate of the detected sub-region
Correlation (sub-region N)
Deviation (sub-region N)
FZ3 Processing Items List Manual

Advertisement

Table of Contents
loading