Key Points For Test Measurement And Adjustment (2D Code+) - Omron XPECTIA FZ3 User Manual

Vision sensor
Hide thumbs Also See for XPECTIA FZ3:
Table of Contents

Advertisement

1.
Tap [Output parameter] in the Item Tab area.
2.
Specify each of the following items.
2
Setting item
Reflect to overall
judgement
Character output
Error output
Error output
character string
Output device

Key Points for Test Measurement and Adjustment (2D Code+)

The following content is displayed in the "Detail result" area as text.
Displayed items
Judge
Index
Character count
Read string
The display items checked in the result settings tab Grade display setting are displayed.
The grade code is displayed with a letter with numeric expression in parentheses, such as "A (4) to F
(0)".
Key Points for Adjustment
Select the adjustment method referring to the following points.
272
2D Code+
Set value
[Factory default]
Enables choosing whether or not the judgement results of
[ON]
this processing unit is reflected in the scene overall
OFF
judgement.
Checked
Set whether to output character strings.
[Unchecked]
Checked
Set whether to output errors.
[Unchecked]
Input the character string output when there is an error.
-
Up to 20 characters can be input.
[RS-232C/
RS-422]
Set the output destination.
Ethernet
Judgement result
Index matched as the result of comparison with the classification comparison character
strings
Number of characters detected
Character strings detected
Description
Description
FZ3 Processing Items List Manual