Stability
Preciseness
When PT is selected
Set value
Setting item
[factory
default]
Angle range
[-180 to 180]
1 to 5
Stability
[3]

Region Setting (Flexible Search)

Use a rectangle to specify the area where the model is searched.
Instead of measuring the entire input image, narrowing the measurement area shortens the processing
time.
1.
In the Item Tab area, tap [Region setting].
2.
Tap [Edit].
The figure setting area is displayed.
3.
Specify the area in which to search for the model.
The rectangle covering the entire screen is set. Adjust the size and position of the rectangle.
4.
Tap [OK].
The area to measure is registered.

Measurement Parameters (Flexible Search)

Specify the search measurement conditions and the judgement conditions for the measurement results.
1.
In the Item Tab area, tap [Measurement].
FZ3 Processing Items List Manual
1 to 15
[The default
value
depend on
the
connected
camera.9 or
12]
1 to 3
[2]
This item specifies the rotation angle range for searching.The normal
direction is clockwise.
If lowering stability does not speed up processing, it is likely that many
candidates have been detected.In this case, specify a larger value for
"Candidate level" or "Stab."
Specify which is to have priority,
measurement stability or speed.
If lowering stability does not speed up
processing, it is likely that many
candidates have been detected.In this
case, specify a larger value for
"Candidate LV" or "Stab."
Specify which is to have priority,
measurement positional precision or
speed.
Description
Flexible Search