3.
In the "Reference color" area, specify the reference color.
This operation is not needed when there is a check at "Auto update reference color" when the
region is registered.
Setting
methods
Tapping the color chart displays the RGB values for the specified color at the
Color chart
bottom.
R, G, B
Set the RGB values with numbers.
If you tap [Auto setting], the average color of the measurement region is displayed
Auto setting
as the reference color.
4.
When the setting has been changed, tap [Measurement] in the Detail area to verify whether
measurements can be made correctly.
5.
Set up the judgement condition.
Setting item
Set value
Color
0 to 442
difference
Color
0 to 221
deviation
For Monochrome Cameras:
1.
In the Item Tab area, tap [Measurement].
FZ3 Processing Items List Manual
Description
Specify the upper and lower limit values for the difference between
the average color of the measurement region and the reference color.
Specify the upper and lower limit values for the deviation of the
average color in the measurement region.
Description
Color Data
2