2.
Enclose the characters in the image.
3.
In the figure setting area, tap [OK].
The measurement region is registered and displayed in the Image Display area.
4.
As necessary, set the items in the "Circle setting" area.
Set value
Setting item
[Factory
default]
Cut out
[0] to 359
angle
Overlap
[0] to 180
5.
Place a check at [Disp transferred image].
Displays the polar transformed image in the image window.
The vertical and horizontal image sizes (in pixels) are displayed overlapped.
FZ3 Processing Items List Manual
Set the angle for starting extraction when the figure is a wide circle.
Set the angle for overlap when the figure is a wide circle.
The overlap angle indicates the end angle of the measurement range.
This is set to measure extra overlapping from the start angle.
Basically, set this larger than the extraction angle.
Description
Polar Transformation
3