Output Parameters (Flexible Search); Key Points For Test Measurement And Adjustment (Flexible Search) - Omron XPECTIA FZ3 User Manual

Vision sensor
Hide thumbs Also See for XPECTIA FZ3:
Table of Contents

Advertisement

Output Parameters (Flexible Search)

Specify how to treat the coordinates to be output to the external device as measurement results.This
item can be changed if necessary.Normally, the factory default value will be used.
Important
After setting up the measurement parameters, changing the output parameters will cause measurement results
to vary accordingly.If the output parameters have been changed, re-specify the measurement, too.
1.
Tap [Output parameter] in the Item Tab area.
2.
Specify each of the following items.
Set value
Setting item
[factory
default]
[After
Output
scroll]
Coordinates
Before
scroll
[OFF]
Calibration
ON
Reflect to
[ON]
overall
OFF
judgement

Key Points for Test Measurement and Adjustment (Flexible Search)

The following content is displayed in the "Detail result" area as text.
Displayed items
Judge
Judgement result
Model number
Model No. of the biggest correlation
Correlation
Correlation value
Position X
X coordinate of the position where the model is detected
Position Y
Y coordinate of the position where the model is detected
Angle
Angle of the position where the model is detected
FZ3 Processing Items List Manual
As measurement results, select whether to output coordinate values
to external devices before or after the position deflection correction is
applied.
Select whether to reflect the calibration in the values output to the
external device as measurement results.
ON: Output the coordinates converted into actual dimensions.
OFF: Output the camera coordinate values.
Enables choosing whether or not the judgement results of this
processing unit is reflected in the scene overall judgement.
Description
Description
Flexible Search
2
59

Advertisement

Table of Contents
loading

Table of Contents