Correlation
0 to 100
Output Parameters (Classification)
Specify how to treat the coordinates to be output to the external device as measurement results.This
item can be changed if necessary.Normally, the factory default value will be used.
Important
After setting up the measurement parameters, changing the output parameters will cause measurement results
●
to vary accordingly.If the output parameters have been changed, re-specify the measurement, too.
1.
Tap [Output parameter] in the Item Tab area.
2.
Specify each of the following items.
Set value
Setting item
[factory
default]
[After
●
Output
scroll]
Coordinates
Before
●
scroll
[OFF]
●
Calibration
ON
●
Reflect to
[ON]
●
overall
OFF
●
judgement
Key Points for Test Measurement and Adjustment (Classification)
The following content is displayed in the "Detail result" area as text.
Displayed items
Judge
Judgement result
Index
Index No. of the biggest correlation
Model number
Model No. of the biggest correlation
Correlation
Correlation with the model
Position X
X coordinate of the position where the model is detected
FZ3 Processing Items List Manual
Specify the range of correlation values that are judged to be
OK.However, when the correlation value of the measurement result is
0, the judgement result will be NG regardless of the lower limit setting.
As measurement results, select whether to output coordinate values
to external devices before or after the position deflection correction is
applied.
Select whether to reflect the calibration in the values output to the
external device as measurement results.
ON: Output the coordinates converted into actual dimensions.
OFF: Output the camera coordinate values.
Enables choosing whether or not the judgement result of this
processing unit is reflected in the scene overall judgement.
Description
Description
Classification