Using the Parallel Output Unit (sold separately)

The Parallel Output Unit (ZG-RPD1) (sold separately) can be used to output
measurement values or judgment results to external devices at high speed.
Measurement values are converted to 16-bit binary data before they are output.

Connecting the Parallel Output Unit

Layout of Output Terminals

1PIN to 16PIN
Parallel output
Signal name: D0 to D15
17PIN
Gate signal
Signal name: GATE
18PIN
Unused
138
Using the Parallel Output Unit (sold separately)
1
2
Pin No.
1
Mount the Parallel Output Unit on
a DIN track.
2
Connect the connector to the RS-
232C connector on the ZG2-WDC.
Signal name Bit assignment Description
1
D0
b0
2
D1
b1
3
D2
b2
4
D3
b3
5
D4
b4
6
D5
b5
7
D6
b6
8
D7
b7
9
D8
b8
10
D9
b9
11
D10
b10
12
D11
b11
13
D12
b12
14
D13
b13
15
D14
b14
16
D15
b15
17
GATE
-
18
-
-
Binary data output pin
GATE si
Unused