Region Setting (Stripes Removal Filter+) - Omron XPECTIA FZ3 User Manual

Vision sensor
Hide thumbs Also See for XPECTIA FZ3:
Table of Contents

Advertisement

Pattern kind: "Cross stripes"
3
V filter size
H filter size
Background pattern
Gain

Region Setting (Stripes Removal Filter+)

It is possible to target the entire screen, but restricting the range can shorten the processing time.
1.
In the Item Tab area, tap [Region setting].
2.
Use the Drawing tools to specify the measurement region.
3.
In the figure setting area, tap [OK].
The area in which to perform filtering is registered.
316
Stripes Removal Filter+
Set value
Setting item
[Factory default]
3 to 63
[21]
3 to 63
[21]
[Checked]
Unchecked
3 to 63
S filter size
[3]
1 to 63
[3]
Description
Set the grid pattern vertical direction width.
Only for "Pattern kind" of grid
Set the grid pattern horizontal direction width.
Only for "Pattern kind" of grid
Place a check here if there is yet another pattern
to eliminate within the grid pattern.
Only for "Pattern kind" of grid
Match this size to the size of the pattern you want
to eliminate from within the grid pattern.
Adjust the contrast of an image after the pattern
suppression.
Specifying a larger value emphasizes the density
differences within the image.