Model Registration (Sensitive Search) - Omron XPECTIA FZ3 User Manual

Vision sensor
Hide thumbs Also See for XPECTIA FZ3:
Table of Contents

Advertisement

List of Sensitive Search Items
Item name
This item registers the pattern characteristic of the measurement image as a model.
Model
Model parameter values can be changed as needed to address unstable measurement results or to
register
increase the processing speed.Normally, the factory default value will be used.
Reference:
This item is used to set up the measurement area.
Region
Instead of measuring the entire input image, narrowing the measurement area shortens the
setting
processing time.
Reference:
This item can be changed if necessary.Specify a position in the model that should be used as the
Detection
detection coordinates during measurement.Usually, the central position of the set model is
point
registered as the detection coordinates.
Reference:
This item can be changed if necessary.Specify the reference position within the camera's field of
Ref. position
view.
Reference:
This item specifies the judgement condition for measurement results.Specify the criteria to judge the
Measurement
measurement result if the X and Y coordinates and the correlation with the model are OK.
Reference:
This item can be changed if necessary.Normally, the factory default value will be used.
Output
Use the output parameter to specify how to handle the coordinates.
parameter
Reference:

Model Registration (Sensitive Search)

Register the parts to measure as the model.
The position at the time of registration is also registered in the model information.Place the
measurement object in the correct position when registering a model.
1.
In the Item Tab area, tap [Model register].
When setting a new model, you do not have to tap [Model register].
2.
Use the drawing tools to specify the model registration range.
3.
To save the entire image used for model registration, place a check at the "Save registered
model" option.Also, when registering a model but not holding the disable setting for the
sub-region set during the last time the model was registered, uncheck the "Keep disabled
setting" option.
FZ3 Processing Items List Manual
Model Registration (Sensitive Search) (p.63)
Region Setting (Sensitive Search) (p.66)
Detection Point (Sensitive Search) (p.67)
Reference Position (Sensitive Search) (p.67)
Measurement Parameters (Sensitive Search) (p.68)
Output Parameters (Sensitive Search) (p.69)