3.
This item selects the color to be detected as edges.
2
Setting
methods
Image
Display area
Color chart
R, G, B
Difference
R, G, B
Detection
mode

Reference Position (Scan Edge Position)

When the measurement region is set, this position is automatically set at the same time as the reference
position.This item can be used to change the reference position to any desired position.
136
Scan Edge Position
Specify a region on the image that includes the target color.The average color of the
specified region is registered.
Tap the reference color on the color chart to specify it.The RGB values for the
specified color are displayed at the bottom.
The color to be detected is set with the RGB values.
This sets the allowable color difference for detecting the edge, using the specified
color as the reference.The larger the difference values, the larger the color range
that is used to detect the edge.
Color IN: The position where a color other than the specified color changes to the
specified color is detected as the edge.
Color OUT: The position where the specified color changes to a color other than the
specified color is detected as the edge.
Description