A<B
A>=B
A>B
3.
Set the branch destination.
Important
In order to avoid measurement processing looping, for the branch destination, set a processing unit
●
5
number that is after the [Conditional Branch].
Make sure to set "End" at the last branch destination to indicate the end of the branch.
●
Reference:
Note
The judgement result for a processing unit is finalized when that processing unit is processed.
●
The overall judgement is finalized when all processing unit measurement is complete.
●
Conditional Branch Settings Examples
The overall judgement result for processing up to the unit number in which the expression is set is
acquired and subsequent measurement is branched according the result.
400
Conditional Branch
If the value from expression A is lower than the value from expression B, moves to
the unit in which "Destination unit" is YES.
If A is equal to or greater than B, moves to the NO unit.
If the value from expression A is equal to that of expression B, or if the value of A is
higher than that of B, moves to the unit in which "Destination unit" is "YES". If B is
higher, moves to the unit with "NO".
If the value from expression A is higher than the value from expression B, moves to
the unit in which "Destination unit" is YES.
If A is equal to or less than B, moves to the NO unit.
End (p.403)
FZ3 Processing Items List Manual