Key Points For Test Measurement And Adjustment (Edge Pitch) - Omron XPECTIA FZ3 User Manual

Vision sensor
Hide thumbs Also See for XPECTIA FZ3:
Table of Contents

Advertisement

2.
Specify each of the following items.
2
Setting item
Output
Coordinates
Calibration
Reflect to
overall
judgement

Key Points for Test Measurement and Adjustment (Edge Pitch)

The following content is displayed in the "Detail result" area as text.
Judge
Number of edges
Average pitch
Max. pitch
Min. pitch
Average width
Max. width
Min. width
Key Points for Adjustment
Select the adjustment method referring to the following points.
Parameter to
be adjusted
Edge color
Measurement If noise is detected as an edge, specify a larger value for "Noise level" and "Noise width".
130
Edge Pitch
Set value
[factory
default]
[After
As measurement results, select whether to output coordinate values
scroll]
to external devices before or after the position deflection correction is
Before
applied.
scroll
Select whether to reflect the calibration in the values output to the
[OFF]
external device as measurement results.
ON
ON: Output the coordinates converted into actual dimensions.
OFF: Output the camera coordinate values.
[ON]
Enables choosing whether or not the judgement results of this
OFF
processing unit is reflected in the scene overall judgement.
Displayed items
If edges cannot be detected properly, specify a larger value for the color variance range.
Description
Description
Judgement result
Number of edges
Average edge pitch
Edge maximum pitch
Edge minimum pitch
Average edge width
Edge maximum width
Edge minimum width
Remedy
FZ3 Processing Items List Manual