Omron XPECTIA FZ3 User Manual page 415

Vision sensor
Hide thumbs Also See for XPECTIA FZ3:
Table of Contents

Advertisement

FZ3-9
/H9
Setting value
[Factory default]
[Refer System (system
-comm -Ethernet)]
The following IP address
Output IP
address
PLC Link setting
Decimal output form
Fixed point
Floating
point
FZ3-9
/H9
Setting item
Offset
[0] to 99999
FZ3 Processing Items List Manual
The settings of the Ethernet window are applied.
Reference:
"User's Manual", "Setting Communication
Specifications (Ethernet - PLC Link)" (p.151)
Reference:
"User's Manual", "Setting Communication
Specifications (Ethernet - Non-procedure)" (p.176)  
Enter the Output IP address.
Specify the Decimal output form for the PLC link.
When precision to 4 digits after the decimal point is required, use a
Floating point.
Data is output multiplied by 1,000.
Example: For 123.456, 0x0001E240
Data is output in floating point format.
Example: For -123.4567, 0xc2f6e979
only
Setting value
[Factory default]
Set the number of offset channels in the output
area.
Description
Description
Data Output
6
413