1.
Tap [Sensitive model setting] in the model parameter.
2.
Set up the sub-model parameter.
Set value
Setting item
[factory default]
Sub-model
0 to 10
number X
[4]
Sub-model
0 to 10
number Y
[4]
1 to 15
[The default value
Stability
depend on the
connected
camera.12 or 15]
1 to 3
Preciseness
[2]
Plain
Checked
inspection
[Unchecked]
FZ3 Processing Items List Manual
Description
This sets the number of divisions of the registered model in the
X direction.
This sets the number of divisions of the registered model in the
Y direction.
Specify which is to have priority, measurement stability or
speed.
If lowering stability does not speed up processing, it is likely that
many candidates have been detected.In this case, specify a
larger value for "Candidate level" or "Stab."
Specify which is to have priority, measurement positional
precision or speed.
Specify whether or not to inspect the plain region.