Omron XPECTIA FZ3 User Manual page 414

Vision sensor
Hide thumbs Also See for XPECTIA FZ3:
Table of Contents

Advertisement

When the "ASCII" output format is selected:
When "ASCII" is set as the output format, set the following items among the format settings.
When "Binary" is set as the Decimal output form, no setting is needed.
6
Setting item
Digits of
integer
Digits of
decimal
Minus
0 suppress
Field
separator
Record
separator
4.
If you have selected "Ethernet" for "Communication method", perform Ethernet settings.
FZ3-3
412
Data Output
Setting value
[Factory default]
Specify the digits of the integer part including the sign. For
positive numbers, the plus sign is not output.
1 to [10]
Example
Setting: 4 digits, Data: -5619
-999 is output.
Specify the number of output digits in the decimal part. When 0
0 to [4]
is selected, the decimal digits will be rounded off.
[-]
Select what is displayed in the sign column for a negative
8
number.
Select the method for adjusting when there is a blank to the left
of the output data.
ON: Insert 0 into the blank digit space.
OFF: Insert a space in the location with no character.
ON
Example
[OFF]
Digits of integer: 5 places, Digits of decimal: 3 places.
When data is 100.000
ON: 00100.000
OFF: _100.000 (_ represents a space)
OFF
[Comma]
Select the separator for output data.
Tab
*The delimiter is obtained from the system.
Space
Delimiter
OFF
Comma
Select the separator each time data is output.
Tab
*The delimiter is obtained from the system.
Space
[Delimiter]
/H3
, FZ3-7
/H7
Description
FZ3 Processing Items List Manual

Advertisement

Table of Contents
loading

Table of Contents