Omron XPECTIA FZ3 User Manual page 130

Vision sensor
Hide thumbs Also See for XPECTIA FZ3:
Table of Contents

Advertisement

Setting item
Edge level
2
Edge color
level
For monochrome cameras:
Important
Up to 1000 edges can be measured, but only a maximum of 256 can be displayed on the screen.
Setting item
Color to
count
Mode
Edge level
3.
If necessary, set each item in the "Noise removal" area.
128
Edge Pitch
Set value
[factory
default]
Specify a color changing level with which the edge is detected.
When the measurement result is lower than the actual number of
0 to 100
edges, specify a smaller value for the edge level.On the other hand,
[50]
when the measurement result is higher than the actual number of
edges, specify a larger value for the edge level.
Reference:
0 to 442
Set the emphasis level for the edge color specified with [Edge color].
[100]
Set value
[factory
default]
[White]
Select an edge color to be measured.
Black
[Normal]
If the pin width or gap is less than 2 pixels, select precise.
Precise
Specify the density change level to be detected as edges.
When the measurement result is lower than the actual number,
specify a smaller value for the edge level (or the minimum level).On
0 to 100
the other hand, when the measurement result is higher than the
[50]
actual number, specify a larger value for the edge level (or the
minimum level).
Reference:
Description
See "User's Manual", "Edge level" (p.304)
Description
See "User's Manual", "Edge level" (p.304)
FZ3 Processing Items List Manual