5.
Set up the judgement condition.
Note
The values beside each item are measurement results of the displayed image.Take these values into
consideration to determine the upper and lower limits.
Setting item
Area
0 to 999999999.9999
-99999.9999 to
Gravity X
99999.9999
-99999.9999 to
Gravity Y
99999.9999

Output Parameters (Gravity and Area)

Specify how to treat the coordinates to be output to the external device as measurement results.This
item can be changed if necessary.Normally, the factory default value will be used.
Important
After setting up the measurement parameters, changing the output parameters will cause measurement results
to vary accordingly.If the output parameters have been changed, re-specify the measurement, too.
1.
Tap [Output parameter] in the Item Tab area.
2.
Specify each of the following items.
FZ3 Processing Items List Manual
Set value
Specify the area to be judged as OK.
Specify the range of X-axis shifting that is judged to be
OK.
Specify the range of Y-axis shifting that is judged to be
OK.
Description
Gravity and Area