3.
In the "List of result display" area, select the object and tap [Edit].
Setting options are displayed. The setting items are different depending on the object.
7
4.
Tap [Change title] as necessary to change titles displayed in the list of result display.
Up to 15 characters can be entered.
When Rectangle, Line, Wide Circle, Ellipse, Arc, or Crosshair Cursor is Selected
Specify display position, style, width, and color of figure.
Setting item
Display
position
Disp pos
Style
Width
Color
424
Result Display
Setting item
Select this if you would like the figure to always display in the same location.Methods
for specifying display position include drawing the figure on the window and
Figure (or
indicating coordinates numerically.
Numerical)
If you would like to always display the figure in a reference position, set up an
expression using "Operation".
Select this when you would like to change display position for each measurement
Operation
based on the measured value.Set up the expression to specify the display position.
Solid
line
Select the line type.
Dashed
line
1 to 10
Modify the line width.
OK Color
Displayed in green.
NG Color
Displayed in red.
Displayed using OK color or NG color based on the judgement results.Specify
Judgement
measurement values subject to judgement and set up respective judgement
conditions.
Arbitrary
Displayed using specified color.Methods for specifying color include specifying by
color
tapping on a color chart and specifying RGB values.
Description