Measurement Results For Which Output Is Possible (Fine Matching) - Omron XPECTIA FZ3 User Manual

Vision sensor
Hide thumbs Also See for XPECTIA FZ3:
Table of Contents

Advertisement

Measurement
When noise is detected as defects/defects cannot be detected
Parameter to be adjusted
Diff. image disp.
Measurement object near plain area
Parameter to be adjusted
Diff. image disp.
When the processing speed is slow
Parameter to be adjusted
Model
Measurement

Measurement Results for Which Output Is Possible (Fine Matching)

The following values can be output using processing items related to results output.It is also possible to
reference measurement values from expressions and other processing units.
Measurement items
Judgement
Quantity
Area
Defect position
Defect position
FZ3 Processing Items List Manual
Set "Labeling" as the "Inspection".
Uncheck" Boundary inspection".
Set "Labeling" as the "Inspection".
Character
string
JG
Judgement result
DA
Number of labeling
AR
Area
X
X coordinate of center of gravity position of measured defects
Y
Y coordinate of center of gravity position of measured defects
Remedy
Adjust "Difference".
Remedy
Uncheck "Normalization".
Remedy
Description
Fine Matching