Output Data List
ZX-GT can output three types of data (measured values, judgment results and results of
calculation performed on multiple Controllers) to external devices. Also, by connecting an
Interface Unit, measured data can be output in binary or by RS-232C communications in
addition to analog output on the Controller I/O cable.
Output path
Controller
Interface
Binary
Unit
RS-232C
When Three Controllers are Connected to Each Other
Calculations can be performed on up to two channels. One of the channels in the
calculation is always CH1. One of the channels in the calculation is always fixed to CH1.
Set the expression on the Controller having the larger CH No.
Output path
Controller
CH1
CH2
CH3
Interface
Binary
Unit
RS-232C
90
Output Data List
Outputs
• Judgment output by HIGH/PASS/LOW
• Output of voltage or current as analog values in accordance with
the measured value
Output of measured values as binary values
Output of measured values/judgments according to command input
Outputs
With calculation
Output of measured value/judgment of CH1
Output of calculation result of
CH1 and CH2
Output of calculation result of
CH1 and CH3
Output of measured value of largest CH
Output of measured value/judgment of CHx or all CHs
Without calculation
Output of measured value/
judgment of CH2
Output of measured value/
judgment of CH3
ZX-GT User's Manual