Note
Defect detection mechanism
After measurement region is drawn, a rectangle (defect detection region) is automatically formed in this
region.While moving the defect detection region around, calculate the RGB color averages at each location and
find the defect detection difference with surrounding defects. This difference is called the defect level. Calculate
the defect level for all defect detection areas. If the maximum value exceeds the judgement value, it is judged
that there are defects in the measurement region.
2
1.
In the Item Tab area, tap [Measurement].
2.
Set the value of each item in the "Defect size" area.
Setting item
Defect size
3.
If necessary, set the value of each item in the "Measurement parameter" area.
For color cameras:
212
Defect
Set value
[Factory
default]
Specify the upper and lower limits of defect detection size based on
the size of scratch or contamination to be detected.A defect detection
region is automatically created with the number of pixels for the
defects size.
The larger the difference between upper and lower limits, the easier to
detect defects/contamination of various sizes.
4
For both upper and lower limits, higher values for defect detection size
8
limits leads to weaker detection sensitivity and shorter processing
12
time.
16
24
32
[64]
[4] to [64]
Description