Binarization (Labeling+) - Omron XPECTIA FZ3 User Manual

Vision sensor
Hide thumbs Also See for XPECTIA FZ3:
Table of Contents

Advertisement

BG color
2
Image kind

Binarization (Labeling+)

When a monochrome camera is connected, the 256-tone grayscale images taken in from the camera
are converted into binary black-and-white images before the images are measured.Converted white
pixels are measured.
This specifies the level for converting grayscale images into binary images.
1.
In the Item Tab area, tap [Binary].
2.
In the "Binary kind" area, set the type of binarization.
Setting item
Binary kind
3.
In the "Binary setting" area, specify the reference density range.
When binarization is selected
194
Labeling+
[Black]
White
The background section outside the extracted image is filled
Red
with the specified colors.
Green
Blue
Measurement
image
[All color
image]
This sets the state of the image to display.
Selection color
image
Binary image
Set value
[Factory
default]
Convert 256-grayscale images to binary images.The binary level that
[Binary]
is the conversion threshold is held constant.
The binary level is not held constant.Stable binary images can be
Dyn
obtained by taking the difference between the input image and that
threshold
input image after it has been subject to brightness averaging. This
option is effective when the lighting is unstable.
Description