Output Parameters (Trend Monitor) - Omron XPECTIA FZ3 User Manual

Vision sensor
Hide thumbs Also See for XPECTIA FZ3:
Table of Contents

Advertisement

40
0, <measured value,latest>
41
1, <measured value,<1 piece>>
42
2, <measured value,<2 piece>>
:
:
1039
999, <measured value,<999 piece>>
Extended format
Line
<Maximum>, <Minimum>, <Deviation>, <Plus 3σ>,
<Plus σ>, <Average>, <Minus σ>, <Minus 3σ>,
1
<Count>, <OK count>, <NG count>, <Warning count>,
<Yield>
2
0, <judgment result,latest>, <measured value,latest>,
3
<Time>
1, <judgment result,<1 piece>>, <measured value,<1
4
piece>>, <Time>
2, <judgment result,<2 piece>>, <measured value,<2
5
piece>>, <Time>
:
:
99999, <judgment result,<99999 piece>>, <Last 99999
100002
Measurement>, <Time>
Note
The default for the file name is the data save date (example: 0410.csv).If it is half-width alphanumeric
characters, it can be changed arbitrarily.
3.
In the "Save setting" area, tap [Save].
The data is saved to USB memory.

Output Parameters (Trend Monitor)

Specifies whether or not the judgement results of this processing unit is reflected in the scene overall
judgement.
1.
Tap [Output parameter] in the Item Tab area.
2.
Choose whether or not to reflect this in the scene overall judgement in "Reflect to overall
judgement" area.
Setting item
Reflect to overall
judgement
FZ3 Processing Items List Manual
Text
Set value
[Factory
default]
[ON]
Enables choosing whether or not the judgement results of this
OFF
processing unit is reflected in the scene overall judgement.
Last
Last 1
Measurement
result
Last 2
(Max: 1000
:
items)
Last 999
Description
Statistical data
Last
Last 1
Measurement
result
(Max:
Last 2
100000
:
items)
Last 99999
Description
Trend Monitor
4
375

Advertisement

Table of Contents
loading

Table of Contents