Displayed items
Judge
Judgement result
Count
Count
Correlation
Correlation value
Position X
X coordinate of the position where the model is detected
Position Y
Y coordinate of the position where the model is detected
Angle
Angle of the position where the model is detected
Key Points for Adjustment
Select the adjustment method referring to the following points.
When the measurement results are unstable
Searching other positions
Parameter to
be adjusted
Specify a larger value for the "Prec."
If the measurement results are unstable only when "Rotation" is selected, specify a smaller value for
the "Skipping angle".
Model
When "Rotation" is selected, if the model shape is complex, uncheck the "Smart mode" option.
parameter
If the image has low contrast or blurred edges, set the "Search mode" to "CR".
If the model image consists of detailed figures, specify a larger value for "Stab."
If the precision is low, place a check at "Sub-pixel".
If images that should be judged OK vary greatly, specify a smaller value for "Candidate LV".
Measurement
If the model image is small and unstable, specify a smaller value for the "Reduction".
The judgement is NG (insufficient memory)
Parameter to be
adjusted
Region setting
Make the search region as small as possible.
Bring "Stab." close to the factory default value.
Bring the "Skipping angle" close to the factory default value.
Model parameter
Specify a smaller value for "Prec.".
When the processing speed is slow
Parameter to
be adjusted
Region
Make the search region as small as possible.
setting
Model
Make the area to register as the model as small as possible.
FZ3 Processing Items List Manual
Description
Remedy
Remedy
Remedy