4.
Set up the judgement condition.
Setting item
Set value
Quantity
0 to 9999
0 to
Area
999999999.9999
-99999.9999
Defect pos X
to
99999.9999
-99999.9999
Defect pos Y
to
99999.9999
Note
Defect coordinates give the center of gravity position of detected defects.

Output Parameters (Fine Matching)

Specify how to treat the coordinates to be output to the external device as measurement results.This
item can be changed if necessary.Normally, the factory default value will be used.
Important
After setting up the measurement parameters, changing the output parameters will cause measurement results
to vary accordingly.If the output parameters have been changed, re-specify the measurement, too.
1.
Tap [Output parameter] in the Item Tab area.
FZ3 Processing Items List Manual
Specify the range of the number of labels that is judged to be OK..
When "Binary area" is used, the white pixels as a whole will be
regarded as one label.
Specify the range of the area that is judged to be OK..
When the "Labeling" is used, the area of the label number will be
specified instead.
Specify the X and Y axis move ranges for the center of gravity
positions that are judged to be OK.
When the "Labeling" is used, the center of gravity position of the label
number will be specified instead.
Specify the X and Y axis move ranges for the center of gravity
positions that are judged to be OK.
When the "Labeling" is used, the center of gravity position of the label
number will be specified instead.
Description
Fine Matching
2
233