Conditional Branch - Omron XPECTIA FZ3 User Manual

Vision sensor
Hide thumbs Also See for XPECTIA FZ3:
Table of Contents

Advertisement

List of Conditional Branch Items
Set
Condition
Expression A
Expression B
YES
Destination
unit
NO

Conditional Branch

Specify expression A and B for the branching conditions.
1.
Set expression A and B separately.
Reference:
Layout of Setting Expression Window (p.333)
2.
Tap [
] in "Condition" to set conditions.
Condition
If the value from expression A is equal to that from expression B, moves to the unit in
A=B
which "Destination unit" is YES.
If not, moves to the NO unit.
If the value from expression A is equal to that of expression B, or if the value of A is
A<=B
lower than that of B, moves to the unit in which "Destination unit" is "YES". If A is
larger, moves to the unit with "NO".
FZ3 Processing Items List Manual
Description
Select the method to compare expression A and B.Compare two
data items that are obtained through conditional expressions.
Set the evaluation expression that is to be the basis for
branching.Set the expression through calculation.
Reference:
Settings (Calculation) (p.330)
Select the destination unit number for when the result of the
comparison is true.
Select the destination unit number for when the result of the
comparison is false.
Description
Conditional Branch
Set value
[factory default]
[A=B]
A<=B
A<B
A>=B
A>B
Up to 256
characters
-1: [End
processing]
0 to 32767:
unit No.
-1: [End
processing]
0 to 32767:
unit No.
399