Maintenance Object Repair Procedures
Table 10-131. TEST #1014 Memory Card Capacity Test
Error
Code
112
2012
2106
2114
2013
2100
2110
10-340
Issue 4 May 2002
Test
Result
ABORT
Memory Card Translation storage at least 98% full.
1. Inform the user of possible need to upgrade to larger flash
card.
2. Replace the memory card with a larger one, or downgrade
the alarm to WARNING (set option).
3. Rerun the test.
ABORT
Internal System Error
1. Retry the command at 1-minute intervals, up to 5 times.
ABORT
Could not locate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals, up to 5 times
ABORT
Memory card not present.
1. Insert formatted memory card into TN2401/TN794 or
TN777B circuit pack slot.
2. Retry the command at 1-minute intervals, up to 5 times.
PASS
The Memory Card Translation storage is less than 98% full.
Description/Recommendation