ANL-LINE (8-Port Analog Line), ANL-NE-L (8-Port Neon
Analog Line)
Table 10-36. TEST #48 Station Present Test — Continued
Error
Code
555-233-123
Test
Result
FAIL
The terminal equipment is not connected to the circuit pack or
the ringing generator may have failed.
1. Remotely test the equipment.
2. If the test fails again, look for RING-GEN errors in the
error log. If present, refer to the RING-GEN (analog ring
generator) Maintenance documentation.
3. Check all of the wiring between the station equipment
and the switch. Then, run the test again.
4. If the test still fails, the set may be defective. Check the
set, and replace it, if necessary.
5. Some terminal equipment (such as a modem) could fail
even when it is connected properly. If this is the case,
disable the test using the change station extension
command (enter 'n' into the 'Test' field). Note that this
action also disables tests 6, 7, 161, and 35 on this port.
PASS
The station is connected properly to the switch. This test may
also pass if no terminal equipment is connected and the
terminal is located far from the switch (that is, it is
off-premises). User-reported troubles on this port should be
investigated by using other port tests, by examining station
wiring, by examining the station, and by ensuring that the
terminal is correctly translated as off-premises or
on-premises.
NOTE:
This test always passes for TN712 Analog circuit packs
prior to Vintage 14 and TN742 circuit packs prior to
Vintage 6.
Description/Recommendation
Continued on next page
Issue 4 May 2002
10-109