Avaya Definity SI Maintenance Manual page 1334

Table of Contents

Advertisement

Maintenance Object Repair Procedures
Table 10-199. TEST #35 Port Diagnostic Test — Continued
Error
Code
61472
0
10-548
Issue 4 May 2002
Test
Result
FAIL
Battery feed test failed. A problem with the incoming CO-line
was detected.
1. Check the incoming CO-line for proper operation. If
warranted, refer the problem to the CO.
2. If the CO-line checks out OK, the failure must be on the
DID port. Replace the circuit pack.
PASS
Current flow was detected for this port.
1. User-reported troubles on this port should be investigated
using other port tests and by examining connections.
2. Refer problem to the CO.
NO
The test could not relate the internal ID to the port (no board).
BOARD
1. Check to ensure that the board translations are correct.
Translate the board, if necessary.
2. Issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board command. This should re-establish
the linkage between the internal ID and the port.
Description/Recommendation
Continued on next page