Avaya Definity SI Maintenance Manual page 1269

Table of Contents

Advertisement

DATA-BD (Data Channel NetPkt Circuit Pack)
4. Reset the selected data channel (test data-module
!
h. Error Type 3840: This error does not affect service and requires no action.
i. Error Type 3999: Circuit pack is hyperactive.
If Error Type 3999:
Does not accompany
Error Type 1538
Does not accompany
Error Type 1538,
Accompanies Error
Type 3586,
System Technician-Demanded Tests: Descriptions
and Error Codes
Investigate errors in the order they appear in the table below.
Order of Investigation
NPE Audit Test (#50)
Control Channel Loop Around Test (#52)
1
D = Destructive; ND = Nondestructive
2
Refer to "DATA-CHL" and "SW-CTL" for other tests associated with DATA-BD
maintenance.
555-233-123
its administered extension.
WARNING:
This command drops all data channel extensions. See DATA-CHL
(Data Channel) Maintenance documentation first.
If the problem persists, replace the TN2401/TN794 NetPkt or
TN777B Netcon circuit pack.
And traffic
volume is:
Heavy
Light
Either
2
ext
Then:
Circuit pack is in service, but sent at
least half hyperactive threshold. With
heavy traffic, this is normal.
Circuit pack is in service, but sent at
least half hyperactive threshold. With
light traffic, this error indicates problem
with circuit pack or its links.
Switch removed hyperactive circuit
pack.
Short Test
Long Test
Sequence
Sequence
X
X
X
Issue 4 May 2002
long), using
1
D/ND
ND
ND
10-483

Advertisement

Table of Contents
loading

Table of Contents