Maintenance Object Repair Procedures
Table 10-165. TEST #0 Dial Tone Test — Continued
Error
Code
1004
1005
1018
2000
10-446
Issue 4 May 2002
Test
Result
ABORT
The port was seized by a user for a valid call. Use the display
port PCSSpp command to determine the trunk group/member
number of the port. Use the status trunk command to
determine the service state of the port. If the service state
indicates that the port is in use, then the port is unavailable for
certain tests. You must wait until the port is idle before
retesting.
1. If the port status is idle, retry the command at 1 minute
intervals for a maximum of 5 times.
ABORT
Trunk has been administered as incoming-only; dial tone can
only be obtained on outgoing trunks. This is a normal
condition.
ABORT
Test has been disabled via administration.
1. Verify that the "Maintenance Tests?" field on the Trunk
Group Form is set to "n". To enable the test, issue the
change trunk-group x command where "x" equals the
number of the trunk group to be tested. Then change the
entry in the "Maintenance Tests?" field on the form to "y."
ABORT
Response to the test was not received within the allowable
time period.
1. Retry the command at 1-minute intervals a maximum of 5
times.
Description/Recommendation