CLAN-BD (Control LAN Circuit Pack)
Link Status Test (#601)
This non-destructive test determines the state of the call control signaling link for
Control LANs. If the signaling link is physically connected, the test sends a test
frame over the link and checks for a response. The test passes only if both the
signaling link is connected and the test frame is successfully transmitted.
A failure may indicate a problem with:
This circuit pack
The packet bus
The packet interface circuit pack
Table 10-153. TEST #601 Link Status Test
Error
Code
Result
1125
ABORT
2012
ABORT
2100
ABORT
555-233-123
Test
RSCL link or C-LAN board not in service.
1. Release the board.
2. Repeat the test.
3. Escalate if the problem persists.
Could not allocate the necessary system resources to run this
test.
Internal system error.
1. Retry command at 1-minute intervals, up to 5 times.
2. If the problem persists, escalate the problem.
Description/Recommendation
Continued on next page