Avaya Definity SI Maintenance Manual page 1194

Table of Contents

Advertisement

Maintenance Object Repair Procedures
Table 10-152. TEST #600 Congestion Query Test
Error
Code
Result
2000
ABORT
2012
ABORT
2100
ABORT
1
FAIL
2
FAIL
3
FAIL
PASS
10-408
Issue 4 May 2002
Test
Did not receive circuit pack test response within the allowable
time period.
1. Retry command at 1-minute intervals, up to 5 times.
2. If the problem persists, reset the circuit pack (reset board
UUCSS).
3. If the problem persists, replace the circuit pack.
Could not allocate the necessary system resources to run test.
Internal system error.
1. Retry the command at 1-minute intervals, up to 5 times.
2. If the problem persists, escalate the problem.
The buffer level is nearly exhausted.
The CLAN is congested, and no buffers are available.
1. Retry command at 1-minute intervals, up to 5 times.
2. If command continues to fail, examine the CLAN port
measurements to determine which ports are heavily utilized
and the processor occupancy of the circuit pack.
Low processor occupancy when CLAN congested indicates
circuit pack failure.
1. If the problem persists, reset the circuit pack (reset board
UUCSS).
2. If congestion recurs, replace the circuit pack.
High processor occupancy indicates the CLAN is congested due
to traffic load.
1. To relieve congestion in the short term, selectively busyout
ports (busyout port UUcSSpp) on the Control LAN circuit
pack.
2. To achieve a more permanent resolution, it may be
necessary to move ports on this circuit pack to other Control
LAN circuit packs.
3. Consider replacing affected CLAN ports with new ports.
The CLAN circuit pack is not operating normally and is
congested.
Hardware setting and attached cable type match CLAN circuit
pack administration. The circuit pack detects no errors.
Description/Recommendation
Continued on next page
555-233-123

Advertisement

Table of Contents
loading

Table of Contents