Avaya Definity SI Maintenance Manual page 1237

Table of Contents

Advertisement

CO-TRK (CO Trunk)
Table 10-166. TEST #3 CO Demand Diagnostic Test — Continued
Error
Code
57481
0
555-233-123
Test
Result
FAIL
On-board test of programmable transmission circuitry failed.
1. Replace the circuit pack.
PASS
This test verifies that the port is able to apply ground for
outgoing calls and detect ground for incoming calls; however, it
does not provide information on whether a CO line is actually
connected. User-reported troubles on this port should be
investigated by using other port tests and by examining trunk or
external wiring.
NO
The test could not relate the internal ID to the port (no board).
BOARD
1. Check to ensure that the board translations are correct.
Translate the board, if necessary.
2. Issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board command. This should re-establish
the linkage between the internal ID and the port.
Description/Recommendation
Continued on next page
Issue 4 May 2002
10-451

Advertisement

Table of Contents
loading