Avaya Definity SI Maintenance Manual page 831

Table of Contents

Advertisement

ANL-24-L (24-Port Analog Line)
Error Log Entries and Test to Clear Values
Table 10-17. 24-Port Analog Line Error Log Entries
Error
Aux
Type
Data
1
0
0
1(a)
40960
40975
40977
15(b)
Any
18
0
130(c)
257(d)
40973
513(e)
769
1025
1281
1537
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
2
Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the
set options command.
Notes:
a. Error Type 1: These are in-line errors and can only be resolved over time.
555-233-123
Alarm
Associated Test
Level
Any
Any
none
Audits and Updates
Test (#36)
busy-out station
WRN
extension
None
WRN
none
Station Present
WRN
Test (#48)
Battery Feed Test
MIN/
(#35)
WRN
Looparound Test
MIN/
(#161)
WRN
Conference Test
MIN/
(#7)
WRN
NPE Crosstalk Test
MIN/
(#6)
WRN
40960 indicates that too many simultaneous incoming ringing
attempts were made on this board. Only 4 ports on a board may ring
simultaneously. A 5th incoming call will cause an inline error from
the board.
On/Off
Board
Test to Clear Value
Any
test port PCSSpp sh r 1
ON
release station
<extension>
ON
test port PCSSpp sh
OFF
test port PCSSpp sh r 2
ON
test port PCSSpp sh r 2
2
ON
test port PCSSpp l r 2
2
ON
test port PCSSpp l r 2
2
ON
test port PCSSpp l r 2
2
Continued on next page
Issue 4 May 2002
10-45

Advertisement

Table of Contents
loading

Table of Contents