DATA-CHL (Data Channel)
Table 10-183. TEST #111 Data Channel Local Loop Back Test — Continued
Error
Code
Result
1000
ABORT
1006
ABORT
1016
ABORT
1018
ABORT
2000
ABORT
555-233-123
Test
Error Code of 1000 can mean one of several things:
a. The target DATA-CHL is busy and, therefore, not
available for use.
b. Could not allocate the necessary system resources to
run this test.
c. Internal system error
If the results of Tests #110 and #111 are both PASS, then there
is a high probability that the target DATA-CHL is not defective.
Proceed with the remaining steps only if it is necessary to
completely test the target DATA-CHL:
1. Determine if errors exist on links using target DATA-CHL
(status link).
2. If there are no errors, busyout the links (busyout link).
3. Determine if no other DATA-CHLs are administered (list
data-module).
4. If no other DATA-CHLs are administered, administer at least
one.
5. Determine if links exist on all non-target DATA-CHLs
(status link).
6. If links exist on all DATA-CHLs, busyout the links (busyout
link).
7. Retry the command at 1-minute intervals, up to 5 times.
8. Restore any busied out links.
Error Code 1006 can mean 1 of 2 problems:
a. Could not allocate the necessary system resources to
run this test.
b. Internal system error.
1. Retry the command at 1-minute intervals, up to 5
times.
a. Could not allocate the necessary system resources to
run this test.
1. Retry the command at 1-minute intervals, up to 5 times.
Test disabled through software patch.
Internal system error