Avaya Definity SI Maintenance Manual page 1496

Table of Contents

Advertisement

Maintenance Object Repair Procedures
Duplication Interface Circuit Pack Invalid
Message Query Test (#272)
The Duplication Interface Circuit Pack Invalid Message Query Test sets the
threshold for the number of bad checksum errors the Duplication Interface circuit
pack detects before reporting the problem to maintenance and queries the
Duplication Interface circuit pack for the number of checksum errors detected.
The error threshold is set to 10. The query causes Duplication Interface circuit
pack firmware to clear its bad checksum error counter. This test is run on both
circuit packs, but has little meaning on Duplication Interface circuit pack B and
should always pass.
Table 10-262. TEST #272 Duplication Interface Circuit Pack
Error
Code
1000
2000
2033
10-710
Issue 4 May 2002
Invalid Message Query Test
Test
Result
ABORT
System resources required to run this test are not available.
ABORT
Response to the test request was not received within the
allowable time period.
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
FAIL
The Duplication Interface circuit pack is receiving an abnormal
number of corrupted messages.
1. First investigate other Duplication Interface circuit pack
tests that are not passing.
2. If this is the only test that fails, investigate and resolve all
alarms against PR-MAINT (Maintenance/Tape Processor).
3. Rerun the test. If the test still fails, follow the procedures
for replacing Common Control circuit packs and replace
the Duplication Interface circuit pack.
4. Rerun the test.
NO
The Duplication Interface circuit pack has failed to handshake
BOARD
with either the active Maintenance/Tape Processor (in the case
of Duplication Interface circuit pack A) or the Duplication
Interface circuit pack A (in the case of Duplication Interface
circuit pack B).
1. Refer to NO BOARD description for the Duplication
Interface Circuit Pack Status Query Test (#315).
PASS
The Duplication Interface circuit pack has not received any bad
messages from either Maintenance/Tape Processor or the
other Duplication Interface circuit pack. All serial links are
operating fine.
Description/Recommendation
Continued on next page
555-233-123

Advertisement

Table of Contents
loading

Table of Contents