Avaya Definity SI Maintenance Manual page 1493

Table of Contents

Advertisement

DUPINT (Duplication Interface Circuit Pack)
The following table summarizes the Aux Data fields.
Aux
Data
1 or
3
2
221
65315
or
65503
Blank,
65313,
or
65501
c. An Aux value of blank or 65317 is valid. The 65317 Aux value means the
Duplication Interface circuit pack reported the trouble, while the blank
means the software detected the trouble.
d. This could be caused by mismatched numbers of Processor Interface,
Packet Control, or NetPkt circuit packs in the two SPEs or by a defective
Duplication Interface circuit pack. If the Duplication Interface circuit pack is
defective and becomes part of the Standby SPE, then memory shadowing
does not work. Follow the procedures given for the FAIL case of Common
Shadow Circuit M-Bus Time-Out Query Test (#285) in the SHDW-CIR
section.
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order they are presented in the table below. By
clearing error codes associated with the Duplication Interface Circuit Pack Status
Query Test, for example, you may also clear errors generated from other tests in
the testing sequence.
For example, you may also clear errors generated from other tests in the testing
sequence.
555-233-123
Duplication Interface circuit pack A lost handshaking with Duplication
Interface circuit pack B.
MTP lost handshaking with the Duplication Interface circuit pack.
Duplication Interface circuit pack reported the trouble.
Duplication Interface circuit pack A lost contact with Duplication
Interface circuit pack B.
If reported against Duplication Interface circuit pack A, Duplication
Interface circuit pack A lost handshaking with Maintenance/Tape
Processor A.
If reported against Duplication Interface circuit pack B, Duplication
Interface circuit pack A lost handshaking with Maintenance/Tape
Processor B.
Description
Issue 4 May 2002
10-707