Avaya Definity SI Maintenance Manual page 1320

Table of Contents

Advertisement

Maintenance Object Repair Procedures
2. NPE Crosstalk Test—verifies the switch connection operation of the circuit
pack. The test also verifies that the trunk circuitry only talks on the selected
time slot on the TDM Bus and never crosses over to time slots reserved for
other connections.
3. Port Diagnostic Test—the battery feed circuitry is tested for hook detection.
4. Port Audit Update Test—updates the DID translation information on
individual ports of the DID trunk. The port translation data consists of
signaling parameters whose values depend on the CO switch connected to
the trunk. These parameters include:
Additional in-line testing is performed while a call is in progress. Thus, in-line
errors may occur during operation. See Error Log table for a description of these
errors. These errors may be reproduced by using the trunk (that is, placing a call)
and checking their occurrence in the Hardware Error Log.
Problems detected during signaling may be caused by faults off-board (in the CO
switch or connections) for which a Warning alarm is raised.
Before a maintenance test can be run on a port, the port must be idle. If an
incoming call seizes the port which is being tested by maintenance, the test is
aborted, and the incoming call proceeds.
For transmission and signaling standard specification, refer to Digital PBX
Standards document RS4648.
Hardware Error Log Entries and Test to Clear
Values
Table 10-196. DID Trunk Error Log Entries
Error
Aux
Type
Data
1
0
0
1 (a)
Any
1 (b)
57476
10-534
Issue 4 May 2002
wink (signal indicating PBX is ready to receive digits) or immediate
start
dial tone or rotary dialing trunk
rotary dialing inter-digit timing
network balance R/RC
disconnect timing
Alarm
Associated Test
Level
Any
Any
None
WRN
None
WRN
On/Off
Board
Test to Clear Value
Any
test port PCSSpp sh r 1
OFF
OFF
Continued on next page
555-233-123

Advertisement

Table of Contents
loading